CathLabHub

26 complications

Coronary

CoronaryPractice case

Coronary perforation

Contrast leaves the vessel during PCI: seal the hole with a balloon at once, then a covered stent for a large vessel or coils or fat for a distal branch, and watch for tamponade.

Bailout: Covered stent through a second guide (ping pong)

Open the card
CoronaryPractice case

Coronary dissection, guide induced and aorto coronary

A flap or stain at the ostium or in the vessel: keep the wire, stop injecting, confirm the true lumen and stent, covering the ostium when the dissection reaches the aorta.

Bailout: Sealing an aorto coronary dissection with an ostial stent

Open the card
CoronaryPractice case

No reflow and slow flow

Flow slows or stops after the vessel is opened, with no dissection or occlusion to fix: deliver small vessel vasodilators into the distal bed and support the pressure.

Bailout: Distal vasodilator delivery through a microcatheter

Open the card
CoronaryPractice case

Coronary air embolism

Air enters the coronary from the manifold or a device: stop injecting, give 100 percent oxygen, aspirate the guide and break the bubbles with a wire.

Bailout: Aspirating coronary air

Open the card
CoronaryPractice case

Acute vessel closure and stent thrombosis

Flow falls during or right after PCI: keep the wire, find the cause (dissection, thrombus, embolization, spasm) and treat that cause.

Bailout: Stent thrombosis in the lab, step by step

Open the card
CoronaryPractice case

Stent loss and retrieval

A stent comes off its balloon: keep the wire through it, then retrieve it with a small balloon or a snare, or deploy or crush it where it lies.

Bailout: Small balloon technique

Open the card
Coronary

Wire fracture and entrapment

A wire will not come back, or comes back short: do not pull hard; free it with a microcatheter or a balloon, and stent over or snare a fragment.

Bailout: Freeing an entrapped wire

Open the card
Coronary

Side branch occlusion

A side branch closes after main vessel stenting: rewire through a distal strut and open it with a balloon; use the jailed wire if you cannot.

Bailout: Rescue of an occluded side branch

Open the card
CoronaryPractice case

Cardiac tamponade and pericardiocentesis

Hypotension with high venous pressure after a perforation or a transseptal puncture: drain the pericardium now, then find and seal the source.

Bailout: Subxiphoid pericardiocentesis

Open the card

Access

AccessPractice case

Access site bleeding and hematoma

A growing lump at the groin or the forearm: compress the artery where it was punctured, not the skin, and grade a radial hematoma to know when to escalate.

Bailout: Holding femoral pressure that works

Open the card
AccessPractice case

Retroperitoneal hemorrhage

Hypotension after femoral access with back or flank pain and no visible hematoma: treat it as a bleed, find it with contralateral angiography and seal it with a balloon.

Bailout: Contralateral balloon tamponade and covered stent

Open the card
Access

Pseudoaneurysm and arteriovenous fistula

A pulsatile groin mass or a continuous bruit days after femoral access: ultrasound it; thrombin injection for a narrow neck pseudoaneurysm, watchful waiting for most fistulas.

Bailout: Ultrasound guided thrombin injection

Open the card
Access

Radial artery spasm and occlusion

A catheter that will not move and a patient in pain: vasodilators, sedation and warmth, never force; and protect radial patency with heparin and patent hemostasis.

Bailout: Freeing a catheter trapped by radial spasm

Open the card
Access

Acute limb ischemia

A cold, pale, painful leg after femoral access or a support device: find the cause with contralateral angiography and restore flow.

Bailout: Antegrade distal perfusion sheath for a large bore cannula

Open the card
Access

Vascular complications of large bore access

Bleeding, dissection or occlusion at a large bore access for TAVR or support: keep a wire across, tamponade with a balloon from the other side, and seal with a covered stent.

Bailout: Crossover balloon occlusion and covered stent

Open the card

Structural

Systemic

SystemicPractice case

Contrast reaction and anaphylaxis

Hives, wheeze, swelling or a falling pressure after contrast: stop the contrast and give epinephrine early for anything beyond skin; antihistamines and steroids do not treat shock.

Bailout: Severe reaction, the first five minutes

Open the card
Systemic

Contrast induced acute kidney injury

A creatinine rise in the days after contrast: prevent it with hydration and the least contrast possible; once it happens, support the kidney.

Bailout: A contrast plan for a patient with advanced kidney disease

Open the card
SystemicPractice case

Bradycardia and asystole

The rate falls during an injection, a right coronary PCI, atherectomy or a vagal reaction: stop the trigger, have the patient cough, atropine, then pace.

Bailout: Pacing through the coronary guidewire

Open the card
SystemicPractice case

Ventricular tachycardia and fibrillation

A wide fast rhythm or VF in the lab: shock immediately when there is no pulse, up to three quick shocks for a witnessed arrest, then treat the ischemia that caused it.

Bailout: Witnessed VF on the table

Open the card
SystemicPractice case

Hypotension and cardiogenic shock in the lab

The pressure falls: first make sure it is real, then sort hypovolemia, pump failure and vasodilation, treat the cause and support the circulation, early with a device when the heart fails.

Bailout: Placing an Impella CP in the lab

Open the card
SystemicPractice case

Stroke during the procedure

A new deficit on the table: note the time, check the glucose and the sedation, and get the stroke team and imaging now; a lab with neurointervention can go straight to angiography.

Bailout: Stroke code from the cath lab

Open the card
Systemic

Atheroembolism (cholesterol embolization)

Days to weeks after a catheter passes a diseased aorta: blue toes with good pulses, livedo and a rising creatinine; no specific treatment, so prevention matters.

Bailout: Catheter technique that lowers the embolic load

Open the card
Systemic

Radiation skin injury

High air kerma on one skin area causes erythema, then ulceration weeks later: track the dose live, move the beam, and follow every patient over 5 Gy.

Bailout: Bringing the dose down during a long case

Open the card

Complications cart

One list of what a lab keeps on or next to the complications cart, drawn from the cards above. Each item opens in the equipment directory where we list it. Print the poster for the cart and check it off at your usual stock check.

Pericardium

Perforation

Retrieval

  • Coronary snares, 2 to 7 mm loopsNot in the directory yet
  • Large multi loop snares, 18 to 30 mmNot in the directory yet
  • Retrieval forceps or bioptomeNot in the directory yet
  • Small balloons, 1.0 to 1.5 mmDirectory: Sapphire II Pro 1.0
  • Guide extension and trapping deviceDirectory: GuideLiner V3, TrapLiner
  • Long sheaths for device retrieval, 12 to 16 FrDirectory: DrySeal Flex introducer sheath

Flow and thrombus

Vascular

Rhythm

Support, nearby

Drugs

Each card has the same ten sections in the same order, so the team knows where to look. Numbers carry a numbered citation to the references at the bottom of the card. Where sources disagree, the card says so in one line. Most cards link to cases in the emergency simulator of the Cath Trainer app, where the complication shows only through its signs and is named in the debrief. Reference material for trained teams, not clinical guidance and not for use in place of a code team. Your local policy and current guidelines govern.